The Next Level of Versatility

The primary goal of hand surgery is to restore function while minimizing the long-term impact of trauma, deformities, and degenerative conditions on patients’ quality of life. 

The Hand System 1.2–2.3 is a fully modular multidirectional and angular stable fixation system for fracture treatment and osteotomies. 

It includes generic straight, T-/L-/Y-shaped, and grid plates, as well as indication specific plate design such as hook plates, scaphoid plates and correction plates for malunions. This unique variety of implants enables surgeons to select the best possible treatment option for each patient’s individual needs. Carefully engineered to provide reliable fixation, these implants support early mobilization, which has been shown in literature to reduce tendon adhesions and joint stiffness. Designed for versatility. Engineered for complex reconstruction.

TriLock

Medartis offers the smallest multidirectional and angular stable hand fixation system. Three sizes of TriLock screws: 1.2, 1.5 and 2.0 mm

Indication-specific plate designs

Hook plates, MC head/neck plate, MC-I base plate, scaphoid plates and correction plates for malunions

No fracture untreated

Generic straight, T-/L-/Y-shaped, and grid plates, as well as indication specific plate design enable surgeons to select the best possible treatment option for each patient’s individual needs

New instruments

Clamp for lag screw technique and minimally invasive approaches. Temporary locking stopper to apply traction before screw locking Optimized reduction, positioning and holding forceps

Treatment Concept

TriLock T-Plate, 5/4 Hole 1.2/1.5

Highlights

  • Internal fixator principle, supporting early mobilization.

  • More screw options to support the subchondral area and the reduction of articular fracture fragments and fractures close to the joint.

  • Increased torsional stability thanks to double bars between screw holes.

  • Soft tissue protection: Low plate profile of 0.8 mm thickness.

Features

TriLock Scaphoid Plates 1.2/1.5

Web GL Scaphoid plate

Highlights

  • Improved anatomical fit: Three different plate designs.

  • High degree of stability due to grid structure and the option for up to three TriLock screws on each side of the nonunion.

  • Anatomical fracture reduction thanks to the anatomical plate shape with a 140° central bend.

  • Two middle bars to keep the bone graft in place.

Features

TriLock Y-Plate 1.2/1.5

Highlights

  • Internal fixator principle, supporting early mobilization.

  • Double bars between screw holes provide increased torsional stability.

  • Soft tissue protection: Low plate profile of 0.8 mm thickness.

Compression Hook Plate 1.2/1.5

Highlights

  • Fixation of small bony avulsions with plate hooks.

  • The various designs widths and sizes offer improved anatomical fit.

    highlight Image
  • Locking (TriLock) and non-locking (fixation) options.

  • Facilitated plate handling and fracture reduction due to small “nose” feature that allows attachment of a holding instrument.

  • Soft tissue protection thanks to low plate profile of 0.6 – 0.8 mm thickness and non-protruding screw heads.

Features

Grid Plates 1.2/1.5

Highlights

  • Increased torsional and bending stability thanks to grid design.

  • TriLock grid plates: Internal fixator principle, supporting early mobilization.

  • Soft tissue protection: Low plate profile of 0.6 – 0.8 mm thickness and non-protruding screw heads.

Features

TriLock Rotation Plate 1.2/1.5

Highlights

  • Laser mark supports positioning of the plate over the planned osteotomy site.

  • Two compression holes enable the osteotomy gap to be closed after rotational correction.

  • Transversal oblong hole close to the joint to perform the osteotomy near the metaphyseal area. It allows for a rotational correction of up to ± 25°.

  • Contouring on the periarticular area is simplified by separate screw holes (“frog design").

  • Soft tissue protection: Low plate profile with 0.8 mm thickness.

Features

TriLock MC-I Base Plate 2.0/2.3

Highlights

  • Narrow screw hole spacing between the metaphysis and diaphysis improves anatomical fit and may help to prevent soft tissue irritation.

  • Multiple proximal screw fixation options to support and fix small marginal fragments.

  • Proximal arms of the plate can easily be contoured and adapted to patient anatomy to allow for very proximal plate positioning.

  • Plate length allows for the treatment of fractures extending into the diaphyseal area.

TriLock T-Plates 2.0/2.3

Highlights

  • Internal fixator principle, supporting early mobilization.

  • Reduction of articular fracture fragments and fractures close to the joint.

  • Increased torsional stability thanks to broader double bars in bridging zones.

  • Soft tissue protection: Low plate profile of 1.3 mm thickness.

Features

TriLock MC Head/Neck Plate 1.2-2.3

Highlights

  • 1.2 or 1.5 mm screws to capture small fracture fragments.

  • 2.0/2.3 mm screw options strengthen of the diaphysis area.

  • Wider spacing of the screw holes where the collateral ligaments attach.

  • Closer spacing of the screw holes in the distal area to facilitate screw placement.

  • Compression hole in the shaft for a 2.0 or 2.3 mm cortical screw.

Features

TriLock Grid Plates 2.0/2.3

WEB GL Gridplate

Highlights

  • Increased torsional and bending stability thanks to grid design.

  • Internal fixator principle, supporting early mobilization.

  • For comminuted fractures in the metaphyseal and diaphyseal region.

  • Straight and offset hole arrangement.

  • Choice of construct stability: Low plate profile with 1.0 mm or 1.3 mm thickness.

Features

TriLock Rotation Correction Plate 2.0/2.3

WEB GL Rotation plate

Highlights

  • Laser mark helps position the plate over the planned osteotomy site.

  • Two compression holes allow the osteotomy gap to be closed after rotational correction.

  • Transversal oblong hole close to the joint to perform the osteotomy near the metaphyseal area. It allows for a rotational correction of up to ± 25°.

  • Contouring on the periarticular area is simplified by separate screw holes (“frog design").

  • Two plate thicknesses available: 1.0 mm and 1.3 mm.

Features

MC Compression Plates 2.0/2.3

Highlights

  • Up to 2 mm compression possible.

  • Design options: straight and Y-shape, long and short.

  • Broader bars in bridging zones.

  • TriLockPLUS combines compression and locking in one step.

  • Low plate profile with 1.3 mm thickness.

Features

Screws

Non-locking
1.2 Cortical Screws,
HexaDrive 4

Non-locking
1.5 Cortical Screws,
HexaDrive 4

Non-locking
2.0 Cortical Screws,
HexaDrive 6

Non-locking
2.3 Cortical Screws,
HexaDrive 6

Locking
1.2 TriLock Screws,
HexaDrive 4

Locking
1.5 TriLock Screws,
HexaDrive 4

Locking
2.0 TriLock Screws,
HexaDrive 6

Selfdrilling
1.5 SpeedTip 
HexaDrive 4

The science behind.

Outcomes of Unstable Scaphoid Nonunion With Segmental Defect Treated With Plate Fixation and Autogenous Cancellous Graft Putnam JG, Mitchell SM, DiGiovanni RM, Stockwell EL, Edwards SG 2019 J Hand Surg Am.

The authors describe the clinical performance of the Scaphoid plate for treating scaphoid non-unions with a segmental defect. They conclude that: "The combination of scaphoid plate fixation and pure cancellous bone grafting for scaphoid nonunion with segmental defects yields reliable union rates and good patient outcomes.”

Plate Fixation With Cancellous Graft for Scaphoid Nonunion With Avascular Necrosis Putnam JG, DiGiovanni RM, Mitchell SM, Castañeda P, Edwards SG. 2019 J Hand Surg Am.

This study reviewed the clinical performance of the Scaphoid Plate for scaphoid nonunions with avascular necrosis, showing excellent union rates and good patient-reported and functional outcomes.

Designed to simplify.

Holding and Positioning Instrument

Firmly hold and position the plate using the plate holding forceps (A-2052).

Lag Screw clamp

The lag screw clamp is available in a left (A-2066.01) and right (A-2066.02) design option to accommodate different fracture locations and surgeon’s preference. Different screw types like cortical, Trilock but also CCS can be used with the Clamp. 

Plate Cutting

Ensure that there are no remaining plate segments in the cutting pliers (visual check). Insert the plate from the front into the open cutting pliers. Always ensure that the labeled side of the plate is facing upwards. Hold the implantable plate segment with your hand during and after cutting.

Temporary fixation using olive K-wires

The olive K-wires can be inserted through the screw holes or through the K-wire holes in the plate.The K-wires with olive are available in a threaded and a non-threaded option, and with different tip lengths  (10 or 15 mm).

Technological Milestones in Osteosynthesis.

TriLock

Multidirectional and angular stable locking, screws can pivot freely by ± 15° in all directions

TriLockPLUS

TriLockPLUS screw holes offer the advantage of locking and compression in one step

HexaDrive

Simplified screw pick-up thanks to self-holding technology

Designed to organize.

  • Compact system
  • Several options for add-on, upgrade or full configurations
  • Easy to use
  • Lightweight components
  • Validated cleaning and sterilization of the implants and instruments 

More Information

Documentation

Results

Show more Show less

It takes more than an implant.

CMX Services

Order your custom implant, saw, or drill guide today, designed specifically for complex cases.

Read More

Clinical Research

Engaged in Research. Partnering with us.

Read More

New Idea Submission

Together we revolutionize treatment options
for orthopedic diseases.

Read More

Request more information.

System Contactform

System Form